Building materials

Wholesale interior doors in Ontario: specs, code rules and import checks

Slab or pre-hung, hollow or solid core, and which Ontario Building Code and federal formaldehyde rules change what you order. Written for dealers, contractors, builders and property managers buying by the pallet or container.

Updated November 22, 2026Reading time about 9 minWritten for Building supply and hardware dealers, contractors, builders and property managers in Ontario

The short version

  1. The buying decision: whether to order slabs or pre-hung units, in which core type, and how many of each width and handing — decided from the drawings before the order goes overseas, not after it lands.
  2. Code drives the widths. Ontario's 2024 Building Code (O. Reg. 163/24) took effect January 1, 2025 12; doorways on a barrier-free path need an 850 mm clear opening 4, and a principal dwelling-unit entrance needs at least 810 mm by 1980 mm 5.
  3. Formaldehyde rules apply to composite-wood doors. Canada's SOR/2021-148 caps MDF at 0.11 ppm and laminated products at 0.05 ppm, and interior doors are not in the exterior/garage-door exemption 9.
  4. Duty is usually not the cost driver. Wood doors under tariff item 4418.29.00, including pre-hung and flush types, carry a Free MFN rate 12; freight, damage and returns are where margin goes.

Every claim below links to the source it comes from. Where a figure is an estimate rather than a published number, this article says so.

Wholesale interior doors in Ontario are bought by the slab or pre-hung unit, specified by core type, size, thickness and handing, and checked against the Ontario Building Code and Canada's formaldehyde rules for composite wood before they ship. Most bulk-order mistakes happen at the takeoff: the wrong width at an accessible suite, the wrong handing on a run of bedrooms, or an MDF door that lands without its bilingual compliance label.

Part one — Specifying the door order

1. Slab or pre-hung: which should you buy wholesale?

A slab is the door leaf alone. A pre-hung unit is the leaf already hinged into a jamb, usually with stops and sometimes casing. The customs tariff treats them as separate statistical lines — 4418.29.00 11 for pre-hung and 4418.29.00 12 for flush doors 12 — and your buyers should too.

  • Buy slabs for replacements in existing frames and unit turnovers.
  • Buy pre-hung for new construction and gut renovations, where framers set rough openings to suit the unit.
  • Fix the handing at order time. Left-hand and right-hand pre-hung units are not interchangeable, so the takeoff must record swing for every opening.
  • Confirm jamb depth against the wall assembly on the drawings.

2. Hollow core, solid core or MDF: which door goes where?

Core type sets weight, sound control, durability and, in some locations, whether the door meets code.

Door typeBest useWatch for
Hollow core (moulded or flush skin)Bedrooms, closets, bathrooms inside a dwelling unitDents easily; not acceptable where a fire separation needs a rated or solid core door
Solid core wood, 45 mmSuite entrance doors to a public corridor, rental turnover unitsPermitted in place of a 20 min rated door in Part 9 buildings only if it conforms to CAN/ULC-S113 7
Solid MDF core / MDF panelShaker-style interiors, better sound control, paint-grade finishComposite wood: formaldehyde limit and labelling under SOR/2021-148 911
Fire-rated door with labelRequired fire separations, service rooms, corridorsNeeds a listed rating and matching frame and hardware
Bifold / bypassClosets, laundry alcovesTrack hardware and opening width; often missed on takeoffs

For the full range of building products we price for projects, see wholesale building materials.

3. Which Ontario Building Code rules change an interior door order?

Ontario now builds to the 2024 Building Code, O. Reg. 163/24, which adopts the National Building Code of Canada 2020 with Ontario amendments 1. It took effect January 1, 2025 2, and O. Reg. 332/12 as it read on December 31, 2024 still applies to construction with a permit issued on or before that date 1. Confirm which edition governs each project.

Barrier-free doorways

Every doorway on a barrier-free path of travel needs a clear opening of at least 850 mm with the door open, measured to OBC Article 3.8.3.3 4. Clear space on the latch side is 600 mm where the door swings toward the user and 300 mm where it swings away 4. Clear opening is measured with the door open, so the slab must be wider than 850 mm; get the slab width from the designer.

In multi-unit residential buildings, at least 15% of suites must have basic accessibility features, including a barrier-free doorway into the kitchen, a bedroom, the living room and a full bathroom 3. Houses, semis, townhouses and duplexes are generally exempt from most accessibility requirements 3.

Entrances, garages and fire separations

The principal entrance to a dwelling unit needs a door at least 810 mm wide by 1980 mm high under Article 9.5.5.1 5. In the 2012/2017 code text, Article 9.10.13.15 requires a door between an attached garage and a dwelling unit to be tight-fitting, weatherstripped and fitted with a self-closing device, and it cannot open into a sleeping room 6. A 45 mm solid core wood door may be used where a 20 min fire-protection rating is permitted, or between a public corridor and a suite, with no more than 6 mm clearance beneath and 3 mm at the sides and top 7; unrated frames for these doors must be at least 38 mm thick 8. For labelled assemblies, see our guide to fire-rated doors under the Ontario Building Code.

4. Get this sourced

Ridgeport sources interior slabs, pre-hung units, solid core suite doors and closet systems for Canadian dealers, contractors and builders, working directly with overseas manufacturers and landing goods under your specification. If you know what you need, request a quote and include the product, quantity, specs or standard required, delivery location and date. A good request reads: "168 primed MDF Shaker pre-hung doors, mixed widths and handing per attached schedule, CANFER labelled, delivered to a Waterloo Region site in May."

Part two — Importing, landing and quantifying

5. What do Canada's formaldehyde rules mean for MDF and composite doors?

The Formaldehyde Emissions from Composite Wood Products Regulations (SOR/2021-148) apply to any composite wood product that contains formaldehyde 9. They came into force 18 months after publication in the Canada Gazette on July 7, 2021 10. A door that incorporates a composite panel and is sold to an end user is a "finished good" under the definition in section 1 9.

  • Emission limits (s. 6(1)): hardwood plywood 0.05 ppm, particleboard 0.09 ppm, MDF 0.11 ppm, thin MDF 0.13 ppm, laminated product 0.05 ppm 9.
  • No interior-door exemption: section 4(h) exempts only exterior or garage doors with under 3% composite wood by volume or using specified low-formaldehyde resins 9.
  • Labels: a bilingual compliance statement such as "CANFER compliant / conforme au CANFER" (or a TSCA Title VI equivalent), plus a date of manufacture on finished goods 11.
  • Laminated products: testing and third-party certification apply from January 7, 2028, for veneers attached with resins other than phenol formaldehyde or no-added-formaldehyde resin 11.
  • Importer duties: identify yourself to the Minister within 60 days of starting, keep records in Canada for 5 years, and provide the declaration of certification within 40 days on request 11.

Importers must notify purchasers of a non-compliant lot within 72 hours of becoming aware 11. Put the label requirement in the purchase order.

6. What duty do imported wood doors pay in Canada?

Doors and their frames and thresholds of non-tropical wood fall under tariff item 4418.29.00, with statistical suffixes for pre-hung, flush and other doors, and the MFN rate on every line is Free 12. Windows under 4418.19 are a different story at 6% to 8% MFN 12, so do not let a mixed doors-and-windows shipment get classified on one line. Loose MDF doorskins sit under heading 4411 at 6% MFN 12. Run the full cost with our landed cost guide.

7. How do you stop warp and damage on a container order?

Doors are bulky and moisture-sensitive; most claims trace back to packing and storage, not manufacturing.

  • Specify that doors ship flat, banded on pallets with corner and edge protection and moisture barrier wrap.
  • Require all six faces, including top and bottom edges, to be primed or sealed before packing.
  • Order full container loads by project or stocking program. Compare LCL vs FCL shipping.
  • Inspect before loading: count by size and handing, check flatness and delamination. See pre-shipment inspection.
  • On arrival, store flat indoors and let doors acclimatize before hanging or finishing.

8. Worked example: a door takeoff for a 24-suite building

A Southwestern Ontario builder has a 24-suite, two-bedroom Part 9 rental permitted under the 2024 code. Each suite has an entrance, two bedrooms, a bathroom, two closets and a utility room.

  1. Accessible suites: 15% of 24 is 3.6, so at least 4 suites need barrier-free doorways into a bedroom and the full bathroom, among other rooms 3.
  2. Wide doors: 4 suites × 2 doorways = 8 doors sized for an 850 mm clear opening 4, each with 600 mm latch-side clearance on the pull side 4.
  3. Entrance doors: 24 doors at least 810 mm × 1980 mm 5, specified as 45 mm solid core to CAN/ULC-S113 where they open to a public corridor 7, in frames at least 38 mm thick if unrated 8.
  4. Remaining swing doors: 24 × 3 (two bedrooms, one bathroom) = 72, minus the 8 wide doors = 64 standard pre-hung interior doors, plus 24 utility doors.
  5. Closets: 24 × 2 = 48 bifold or bypass units.
LineQtySpec note
Suite entrance, solid core2445 mm, CAN/ULC-S113 7
Barrier-free interior8850 mm clear 4
Standard interior pre-hung64Split by handing from plans
Utility room24Confirm width on drawings
Closet bifold/bypass48Track and hardware included
Total168Composite cores CANFER labelled 11

Add a few spares per line for install damage and record handing for every swing door. For larger projects, see institutional doors and building materials.

9. What to send us for a quote

A door quote is only as accurate as the schedule behind it. Send:

  • Door schedule: quantity per type, width, height, thickness and handing
  • Slab or pre-hung, with jamb depth and casing if pre-hung
  • Core type and face: hollow, solid wood, solid MDF, moulded or flush
  • Code requirements: barrier-free openings, CAN/ULC-S113 solid core, any labelled fire-rated doors
  • Formaldehyde compliance: CANFER labelling required on composite products
  • Finish: primed, pre-finished or unfinished, plus hardware prep (bore, hinge spec)
  • Packing and delivery: site or yard address, unloading equipment, required date
  • Phasing: one container or staged deliveries by floor

Request a quote, or if you resell doors regularly, open a trade account.

From brief to landed

Let us build it with you

Our sourcing specialists handle factory selection, samples, packaging design, certification, inspection and freight — and hand you a finished, compliant product in Canada.

Start a brand project

Manufacturers

Make private label for Canadian brands?

Join the Ridgeport supplier network and get your line in front of Canadian buyers looking for exactly this.

List your line

Common questions

What width does an interior door need to be under the Ontario Building Code?

Doorways on a barrier-free path of travel need a clear opening of at least 850 mm with the door open 4. The principal entrance to a dwelling unit needs a door at least 810 mm wide and 1980 mm high under Article 9.5.5.1 5. Other room sizes depend on the edition that applies to the permit, so confirm with the designer.

Do MDF interior doors need formaldehyde certification in Canada?

Yes. Canada's Formaldehyde Emissions from Composite Wood Products Regulations (SOR/2021-148) set an MDF limit of 0.11 ppm and cover finished goods that incorporate composite panels, and the door exemption covers only exterior and garage doors 9. Products need a bilingual compliance label such as "CANFER compliant / conforme au CANFER" 11.

Does the door between a garage and a house need to be self-closing in Ontario?

Yes. Article 9.10.13.15 of the Ontario Building Code text requires a door between an attached or built-in garage and a dwelling unit to be tight-fitting, weatherstripped and fitted with a self-closing device, and it cannot be located in a room intended for sleeping 6. Check the article against the 2024 edition for permits issued after December 31, 2024 1.

Can a solid core wood door be used instead of a fire-rated door?

In Part 9 buildings, a 45 mm solid core wood door conforming to CAN/ULC-S113 is permitted where a 20 min fire-protection rating is permitted or between a public corridor and a suite 7. It must have no more than 6 mm clearance beneath and 3 mm at the sides and top 7, and an unrated wood frame must be at least 38 mm thick 8.

Sources

Every figure and rule above comes from one of these. Where this article draws a conclusion the source does not state literally, or gives an estimate rather than a published number, it says so in the text.

  1. Government of Ontario (e-Laws) — O. Reg. 163/24: Building Code
  2. Township of Springwater — New Ontario Building Code changes effective January 1st, 2025
  3. Government of Ontario — Accessibility in Ontario's Building Code
  4. Trillium Architectural Products — Top 5 requirements for barrier-free doors (OBC 2024)
  5. Ontario Building Officials Association (BCAS) — 2024 OBC update: exterior egress dimensions for an individual dwelling unit
  6. The Ontario Building Code (buildingcode.online) — 9.10.13.15 Doors between garages and dwelling units
  7. The Ontario Building Code (buildingcode.online) — 9.10.13.2 Solid core wood door as a closure
  8. The Ontario Building Code (buildingcode.online) — 9.10.13.3 Unrated wood door frames
  9. Justice Laws Website — Formaldehyde Emissions from Composite Wood Products Regulations (SOR/2021-148)
  10. Canada Gazette, Part II — SOR/2021-148, July 7, 2021
  11. Health Canada — Guidance document on the Formaldehyde Emissions from Composite Wood Products Regulations
  12. Canada Border Services Agency — Customs Tariff Chapter 44 (T2026-2)

Last reviewed November 22, 2026. Rules and rates change. If you find something here that has gone out of date, tell us and we will fix it. This guide is general information, not legal or customs advice.