Fire Code compliance
Commercial kitchen hood cleaning in Ontario: the Fire Code schedule, records and the supplies you reorder
What the Ontario Fire Code and NFPA 96 expect from a commercial cooking exhaust system, how often hoods and ducts get cleaned by cooking volume, what fire inspectors ask to see, and the filters, extinguishers and cleaning supplies a kitchen keeps on reorder.
The short version
- The Ontario Fire Code points to NFPA 96. Cooking operations that produce grease-laden vapours need an exhaust system and fire protection system kept in compliance with NFPA 96 and Division B, 2.6.1.12 2.
- Cleaning frequency follows cooking volume. Fire services summarise NFPA 96 as monthly for solid fuel, quarterly for high volume, semi-annual for moderate and annual for low volume 4.
- Suppression systems are serviced every six months, extinguishers yearly, and the paperwork stays on site for at least two years 3.
- Your buying decision: keep a spare set of correctly sized, listed baffle filters plus Class K extinguishers, signage and degreaser on a standing reorder, so a cleaning visit or inspection never finds a gap.
Every claim below links to the source it comes from. Where a figure is an estimate rather than a published number, this article says so.
Grease in a kitchen exhaust hood is fuel sitting directly above an open flame. That is why fire inspectors open the hood, look at the filters and ask for the last cleaning certificate before almost anything else. Here is what Ontario fire services expect, how often the system needs professional attention, what records to keep, and which supplies the kitchen keeps on hand.
Part one — the rules
1. What the Ontario Fire Code requires
The Fire Code is a regulation under the Fire Protection and Prevention Act, 1997. It sets minimum fire safety requirements for existing buildings, and municipal fire departments enforce it 1. For kitchens, the key requirement is short:
- All commercial cooking operations that produce grease-laden vapours must be equipped and maintained with an exhaust system and a fire protection system in compliance with NFPA 96 and the Ontario Fire Code, Division B, 2.6.1.12 2.
- A system designed for a specific hazard must be maintained as originally designed. If you change the line-up of appliances or modify the system, check with the building department about a permit 2.
- After an appliance is relocated or replaced, the suppression system should be assessed by a qualified fire safety supplier to confirm it still complies 4.
NFPA 96 is the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations. Its chapters on grease removal devices, exhaust fans and auxiliary equipment are what Ontario building and fire officials point to for new installations 7.
2. Who is responsible
The owner of the building is responsible for complying with the Fire Code, except where the Code says otherwise 1. Tenants are not off the hook: Barrie Fire notes that business owners have Fire Code obligations and can be held accountable whether they own the building or only operate in it 3. The usual split looks like this:
| Task | Typically done by |
|---|---|
| Cleaning the hood, ducts and fan to bare metal | An approved cleaning company acceptable to the local fire department 4 |
| Semi-annual suppression system check and test | A qualified fire protection company 4 |
| Annual extinguisher service | A qualified firm; fire services do not do this themselves 6 |
| Monthly extinguisher visual check | The owner or kitchen manager 6 |
| Daily and weekly filter cleaning, degreasing, housekeeping | Kitchen staff |
| Keeping records on site | The business owner 23 |
If the landlord holds contracts for building-wide systems such as the fire alarm, Barrie asks tenants to obtain the inspection report from the property owner and have it on site for the fire inspection 2.
3. How often hoods and ducts must be cleaned
North Bay Fire sets out the NFPA 96 schedule plainly: the entire system is cleaned of grease and oil residue, to bare metal, at intervals based on cooking volume and fuel 4.
| Type or volume of cooking | Examples given | Cleaning interval 4 |
|---|---|---|
| Solid fuel | Wood or pellet fired appliances | Monthly |
| High volume | 24-hour cooking, charbroiling, wok cooking | Quarterly |
| Moderate volume | Not specified | Semi-annually |
| Low volume | Churches, pizza ovens | Annually |
Some Ontario fire services simply ask for a semi-annual hood cleaning report alongside the semi-annual suppression report as part of a pre-inspection checklist 5. Treat the table as the minimum. If a technician finds heavy build-up at a visit, shorten the interval rather than waiting for an inspector to do it for you.
School, hospital and long-term care kitchens
Institutional kitchens follow the same rules. Their difference is risk: long-term care residents cannot evacuate quickly, and the province's guidebook asks whether the fire department has inspected the home and approved a fire safety plan that is reviewed regularly 11. Put hood cleaning dates in the same calendar as fire drills and alarm testing. Cafeterias that only run lunch service on school days may fall into the lower-volume bands, but confirm with your fire service rather than assuming.
4. Suppression systems and Class K extinguishers
The hood suppression system and the portable extinguisher work as a pair. Key points from Ontario fire services:
- Suppression service every six months by a qualified company 4. Barrie lists the 6-month suppression system inspection as a record business owners must produce 2.
- Fuel and heat shut-off. Activating the extinguishing system must automatically shut off all fuel and heat to the protected equipment, and it must connect to the building fire alarm where one exists 7.
- Type K extinguisher. Kitchens with commercial hoods and suppression systems need a Type K unit designed for use with these systems 6; Sarnia's checklist lists both an ABC and a Type K extinguisher in the kitchen 5.
- Monthly visual check, annual service. Each extinguisher must be visually checked every month for tampering or damage and serviced once a year by a qualified firm, with the tag updated 6.
- Gas appliances require annual testing by a qualified TSSA inspector 4.
On equipment standards, Alberta's code interpretation is a useful reference: suppression systems protecting vegetable oil or animal fat cooking are expected to meet ANSI/UL 300 or ULC/ORD-C1254.6, and a Class K extinguisher is required within 9.15 m of the appliances 8. NFPA 10, as summarised by an insurer's loss-control bulletin, also calls for a placard near the extinguisher stating that the fixed system should be activated before the extinguisher is used, because the Class K unit is the second line of defence 9. Confirm with your contractor what your local fire service applies.
5. Grease filters: baffle versus mesh
The filters are the first grease barrier and the part your staff touch every day. A fire-service technical bulletin on grease filters notes that modern baffle filters have larger surface areas than the mesh filters that were predominant for many years, and that the recognised testing standard for exhaust-duct grease filters is UL 1046 10. The same bulletin sets basic installation rules 10:
- Filters sit in frames so they can be removed easily for cleaning.
- They are mounted at an angle steeper than 45 degrees from horizontal.
- A drip tray sits below the lower edge of the filters.
One more rule from North Bay: the filters must stay in the hood until every appliance underneath is turned off 4. Never run the line with filters out for washing. That is the single best reason to own a spare set: swap in clean filters at close, wash the dirty set, and the hood is never bare.
Part two — get this sourced
6. Get this sourced
Ridgeport Supply Co. does not clean hoods. We source the supplies your kitchen and your contractors reorder: baffle filters and spares, degreasers, gloves and PPE, extinguisher signage and housekeeping items, from overseas manufacturers and established channels. Request a quote and send the product, quantity, the specs or standard you need (for example filter dimensions or UL 1046 listing), and the delivery location and date. Browse related lines under commercial kitchen supplies.
Part three — inspection, records and reordering
7. What inspectors look for and the records to keep
Fire inspectors work from documents first, then the kitchen. Barrie's business licence inspection asks owners to produce, where applicable 2:
- Duct cleaning and inspection reports
- The 6-month suppression system inspection
- Annual portable fire extinguisher maintenance
- Annual fire alarm, sprinkler and emergency lighting inspections
Records must be kept at the building for the fire department to examine and kept for at least two years after they are prepared 3. Oshawa may also ask for certificates of inspection and maintenance to be forwarded to the fire service 7. On the floor, Sarnia's pre-inspection checklist includes clean hood filters, the ABC and Type K extinguishers, exit signs, emergency lighting and unobstructed exits 5.
8. Budgeting and what to reorder
Contractor visits are scheduled costs; the consumables between visits are where kitchens get caught short. Plan a standing order for:
| Item | Why it matters | Reorder trigger |
|---|---|---|
| Baffle grease filters, spare set | Filters must stay in place while cooking 4 | Damaged, warped or short of a full spare set |
| Filter degreaser and soak tank chemical | Keeps filters cleanable between professional visits | Monthly usage |
| Drip trays and grease cups | Part of the filter installation 10 | Cracked or missing |
| Class K extinguisher and placard | Required near hooded appliances 69 | Missing tag or failed monthly check |
| Nitrile gloves, aprons, eye protection | Staff handling hot grease and chemicals | Case usage |
| Inspection log binder or tags | Two-year record retention 3 | Each new year |
Budget the professional side by counting visits: a high-volume line on a quarterly schedule 4 plus two suppression services 4 means six contractor visits a year before any repairs. See our guide to restaurant janitorial and sanitation supplies for the cleaning chemistry side.
9. Hood and exhaust compliance checklist
- Confirm your cooking volume band and set the cleaning interval 4.
- Book the next hood and duct cleaning with an approved company and file the report 4.
- Book the semi-annual suppression service and keep the tag current 4.
- Check every extinguisher monthly and log it; book the annual service 6.
- Make sure a Type K extinguisher and its placard are at the cooking line 69.
- Keep a spare set of filters so the hood is never run without them 4.
- Book the annual TSSA gas appliance test 4.
- Keep two years of reports in a binder at the building 3.
- Before moving or replacing an appliance, call your suppression contractor 4.
10. What to send us for a quote
Send these details and we will source to your specification:
- Filter dimensions (height, width, depth) and quantity per hood, plus how many spare sets
- Material and listing required, such as stainless or aluminium baffle and UL 1046
- Degreaser or soak chemical type and pack size, and any facility chemical policy
- Extinguisher signage, placards and PPE quantities
- Number of sites, delivery address and the date you need it on site
- Whether this is a one-time order or a standing reorder
Request a quote or read how our sourcing works.
Institutional supply
Supplying a school, office or facility?
We source and supply first aid kits, safety signage, air purifiers and facility products for Ontario institutions, quoted delivered in Canadian dollars. See institutional supply.
Request a quoteBuying regularly?
Open a wholesale account
Trade pricing, the full product catalogue and live status on every request and order.
Apply to buyCommon questions
How often does a commercial kitchen hood need cleaning in Ontario?
It depends on cooking volume. Fire services summarising NFPA 96 give monthly for solid fuel, quarterly for high-volume cooking such as charbroiling or wok cooking, semi-annually for moderate volume and annually for low volume 4.
Which Ontario Fire Code section covers kitchen exhaust systems?
Barrie Fire cites Division B, 2.6.1.12 of the Ontario Fire Code, which requires cooking operations producing grease-laden vapours to have an exhaust and fire protection system maintained in compliance with NFPA 96 2.
How often is a kitchen fire suppression system inspected?
Do restaurants in Ontario need a Class K extinguisher?
Kitchens with commercial hoods and suppression systems need a Type K extinguisher designed for use with those systems, checked monthly and serviced annually 6.
How long do I keep hood cleaning and suppression records?
Keep them at the building for the fire department to examine, for at least two years after they are prepared 3.
Sources
Every figure and rule above comes from one of these. Where this article draws a conclusion the source does not state literally, or gives an estimate rather than a published number, it says so in the text.
- Government of Ontario — Fire safety legislation and Ontario's Fire Code
- City of Barrie — Business licence inspection requirements
- City of Barrie — Business owner fire safety responsibilities
- North Bay Fire and Emergency Services — Commercial cooking equipment
- City of Sarnia — Commercial cooking operations pre-fire inspection checklist
- City of St. Catharines — Fire extinguishers
- City of Oshawa — Requirements for commercial cooking equipment
- Alberta Municipal Affairs — Fixed fire suppression and exhaust systems: cooking and cleaning (14-FCI-005)
- Grinnell Mutual — Class K fire extinguishers (loss control bulletin)
- Alaska Division of Fire and Life Safety — Commercial cooking: grease filters for exhaust ducts
- Government of Ontario — Long-term care home fire safety
Last reviewed November 22, 2026. Rules and rates change. If you find something here that has gone out of date, tell us and we will fix it. This guide is general information, not legal or customs advice.